Command Name

Short

Description

Parameter

Default

PPERSIST

PP

Causes the TNC to use the PERSIST/SLOTTIME method
when ON, or the DWAIT method when OFF.

ON/ OFF

ON

RAMTEST

RAMTEST

Checks the RAM after clearing it.

READ

R

Specifi es one or more message numbers to be read from the
TNC mailbox.

RESET

RESET

Restores the default status for all the commands.

RESPTIME

RES

Specifi es the acknowledgment packet transmission delay.
The unit of the parameter is 100 milliseconds.

0 ~ 250

5

RESTART

RESTART

Causes the TNC to function as if it is switched OFF then ON.

RETRY

RE

Specifi es the number of transmission retries.

0 ~ 15

10

ROUTE

ROU

When ON and receiving a packet forwarded by a PBBS,
leaves the included route information.

ON/ OFF

ON

SENDPAC

SE

Specifi es a character which forces a packet to be sent.

0 ~ $7F

$0D

SLOTTIME

SL

Specifi es the period of random number generation intervals
for the PERSIST/SLOTTIME method. The unit of the
parameter is 10 milliseconds.

0 ~ 250

3

SPATH

SPATH

Specifi es digipeater callsigns to be added when the UISSID
parameter in a received packet is 9 or 13.

Call1, ... call7

STREAMCA

STREAMC

When ON and multiple connections take place, receiving a
packet causes the TNC to display the callsign.

ON/ OFF

ON

STREAMDB

STREAMD

When ON, causes the TNC to display a stream switch
character included in a received packet.

ON/ OFF

OFF

STREAMSW

STR

Specifi es a character to be used for switching streams.

0 ~ $7F

$01

TOUT

TOUT

Specifi es the time-out time of the TNC mailbox. When no
packet is received within the specifi ed time, a disconnect
takes place. The unit of the parameter is 10 seconds.

0 ~ 250

30

TRACE

TRAC

When ON, causes the TNC to display all received packets in
their entirety.

ON/ OFF

OFF

TRANS

T

Causes the TNC to exit Command mode and enter
Transparent mode. To restore Command mode, press and
hold [Ctrl], then press [C] three times.

TRFLOW

TRF

When ON, causes the TNC to respond to software fl ow
control from the computer in Transparent mode.

ON/ OFF

OFF

TRIES

TRI

Specifi es the number of transmission retries programmed in
the retry counter.

0 ~ 15

0

TXDELAY

TX

Specifi es the time delay between PTT ON and start of
transmission. The unit of the parameter is 10 milliseconds.

0 ~ 120

50

TXFLOW

TXF

When ON, allows the TNC to send a software fl ow control
(XON and XOFF) to the computer in Transparent mode.

ON/ OFF

OFF

UICHECK

UIC

Does not forward the same UI packet as one received
within the time specifi ed by this command. The unit of the
parameter is 1 second.

0 ~ 250

28

UIDIGI

UI

When receiving a UI packet which includes the parameter
specifi ed by this command, replaces the parameter with the
MYCALL parameter and forwards the packet.

OFF/

ON Call1, ... call14

OFF

UIDWAIT

UIDW

When ON and digipeating, causes the TNC to use the
DWAIT and PPERSIST settings.

ON/ OFF

OFF

UIFLOOD

UIF

Specifi es how received UI packets, which include WIDEN-N
or TRACEN-N parameters, are processed. Enter WIDE or
TRACE before ID, NOID, or FIRST; ex. WIDE,FIRST. With
ID selected, deletes the relayed digipeaters and adds the
MYCALL parameter. With NOID, merely decrements N-N;
ex. 4-3 to 4-2. With FIRST, adds the MYCALL parameter
only when serving as the fi rst digipeater.

ID/ NOID/ FIRST

ID

UISSID

UIS

When ON, causes the TNC to process received UI packets
depending on included destination SSIDs.

ON/ OFF