Command Name

Short

Description

Parameter

Default

PPERSIST

PP

Causes the TNC to use the PERSIST/SLOTTIME method
when ON, or the DWAIT method when OFF.

ON/ OFF

ON

RAMTEST

RAMTEST

Checks the RAM after clearing it.

−

−

READ

R

Specifi es one or more message numbers to be read from the
TNC mailbox.

−

−

RESET

RESET

Restores the default status for all the commands.

−

−

RESPTIME

RES

Specifi es the acknowledgment packet transmission delay.
The unit of the parameter is 100 milliseconds.

0 ~ 250

5

RESTART

RESTART

Causes the TNC to function as if it is switched OFF then ON.

−

−

RETRY

RE

Specifi es the number of transmission retries.

0 ~ 15

10

ROUTE

ROU

When ON and receiving a packet forwarded by a PBBS,
leaves the included route information.

ON/ OFF

ON

SENDPAC

SE

Specifi es a character which forces a packet to be sent.

0 ~ $7F

$0D

SLOTTIME

SL

Specifi es the period of random number generation intervals
for the PERSIST/SLOTTIME method. The unit of the
parameter is 10 milliseconds.

0 ~ 250

3

SPATH

SPATH

Specifi es digipeater callsigns to be added when the UISSID
parameter in a received packet is 9 or 13.

Call1, ... call7

−

STREAMCA

STREAMC

When ON and multiple connections take place, receiving a
packet causes the TNC to display the callsign.

ON/ OFF

ON

STREAMDB

STREAMD

When ON, causes the TNC to display a stream switch
character included in a received packet.

ON/ OFF

OFF

STREAMSW

STR

Specifi es a character to be used for switching streams.

0 ~ $7F

$01

TOUT

TOUT

Specifi es the time-out time of the TNC mailbox. When no
packet is received within the specifi ed time, a disconnect
takes place. The unit of the parameter is 10 seconds.

0 ~ 250

30

TRACE

TRAC

When ON, causes the TNC to display all received packets in
their entirety.

ON/ OFF

OFF

TRANS

T

Causes the TNC to exit Command mode and enter
Transparent mode. To restore Command mode, press and
hold [Ctrl], then press [C] three times.

−

−

TRFLOW

TRF

When ON, causes the TNC to respond to software fl ow
control from the computer in Transparent mode.

ON/ OFF

OFF

TRIES

TRI

Specifi es the number of transmission retries programmed in
the retry counter.

0 ~ 15

0

TXDELAY

TX

Specifi es the time delay between PTT ON and start of
transmission. The unit of the parameter is 10 milliseconds.

0 ~ 120

50

TXFLOW

TXF

When ON, allows the TNC to send a software fl ow control
(XON and XOFF) to the computer in Transparent mode.

ON/ OFF

OFF

UICHECK

UIC

Does not forward the same UI packet as one received
within the time specifi ed by this command. The unit of the
parameter is 1 second.

0 ~ 250

28

UIDIGI

UI

When receiving a UI packet which includes the parameter
specifi ed by this command, replaces the parameter with the
MYCALL parameter and forwards the packet.

OFF/

ON Call1, ... call14

OFF

UIDWAIT

UIDW

When ON and digipeating, causes the TNC to use the
DWAIT and PPERSIST settings.

ON/ OFF

OFF

UIFLOOD

UIF

Specifi es how received UI packets, which include WIDEN-N
or TRACEN-N parameters, are processed. Enter WIDE or
TRACE before ID, NOID, or FIRST; ex. WIDE,FIRST. With
ID selected, deletes the relayed digipeaters and adds the
MYCALL parameter. With NOID, merely decrements N-N;
ex. 4-3 to 4-2. With FIRST, adds the MYCALL parameter
only when serving as the fi rst digipeater.

ID/ NOID/ FIRST

ID

UISSID

UIS

When ON, causes the TNC to process received UI packets
depending on included destination SSIDs.

ON/ OFF

OFF