Section 2. Installation
11
e “D” Bezel configuration.)
Figure 2-5 shows the position for mounting the IntelliStripe 310 with the “D” Bezel attached.
The mounting holes are shown in the bottom view. The "A" Bezel is attached to the unit by the
"A" Bezel Retaining screws also shown in the bottom view. Because the “D” Bezel is
symmetrical, the unit may be mounted from the top or bottom, depending on the desired card
orientation. (Note that no LED is used with th
.088"
2.24 mm
1.95"
49.53 mm
5.60"
142.24 mm
3.06"
77.72 mm
.240"
6.10 mm
.410"
10.41 mm
5.60"
142.24 mm
51.36 mm
45.97 mm
#6 – 32 Thread
Mounting Holes –
.38" Internal
Thread Clearance
"A" Bezel
Retaining Screws
"A" Bezel
Retaining
Screw
Bottom View
Top View
2.022"
1.81"
Side View
.365"
9.27 mm
.800"
20.32 mm
1.165"
29.59 mm
1.233"
31.32 mm
Figure 2-5. “D” Bezel Mounting – Top, Side, and Bottom Views