IntelliStripe 310 Command Reference


12

SOFTWARE RESET COMMAND

Command ID: 80 (Hex)
Description:

This command is used to reset the device. This will put the device in its power on state. The
device should be allowed time to power up (we recommend three seconds) before trying to
communicate with the device.

Request Message Data: None

Response Message Data: None

Response Message Result Codes:

Success = 00 (Hex)

The command completed successfully.

Example Request:

Field MTYP

APPL

CMND

RC

Byte 1

2

3

4

Value (Hex)

00

00

80

00

Example Response:

Field MTYP

APPL

CMND

RC

Byte 1

2

3

4

Value (Hex)

40

00

80

00