IntelliStripe 310 Command Reference


24

LED STATE PROPERTY

Property ID: 00 (Hex)

Property Type: Dword

Power Up/Reset Value: 0 (OFF)

Get/Set support: Both

Description:

Changing this property changes the LED state. The LED state can be retrieved by getting this
property.

Values:

Value LED

State

0 OFF
1 RED
2 GREEN


Example Set Property Request:

Field MTYP

APPL

CMND

RC

PTYP

PID

Byte

1

2 3 4 5 6

Value

(Hex)

00

81 01 00 01 00

Field PVAL
Byte

7 - 10

Value (Hex)

02 00 00 00 (GREEN)

Example Set Property Response:

Field MTYP

APPL

CMND

RC

Byte 1

2

3

4

Value (Hex)

40

81

01

00