Keypad type, Telephone calculator, Send data after error – MagTek MINI MICR WEDGE User Manual

Page 19: Table 1-1. specifications

Advertising
background image

Section 4. Commands

11

Table 4-2. Error and Status Codes

PRIORITY CODE

TYPE

DESCRIPTION

9

01

Error

No MICR data: no transit and no account found

8 09

Status

Mexican

check

7 08

Status

Canadian

check

6

05

Error

Transit error: No transit, bad character, bad length,
bad check digit

5

07

Error

Account error: No account, bad character

4

04

Error

Check # error: Bad character in check number

4

04

Status

No check number

3

03

Status

Low MICR signal, good read

2 10

Status

Business

check

1

11

Status

Amount field present

0

00

Status

No error, check OK

Notes:

The LED will turn red on all error conditions.

The absence of a check number is not considered an error.

If a multiple error condition occurs, the error or status code with the highest priority is
reported.

All unreadable MICR characters are transmitted as a “?” ASCII character (hex 3F), except for
Format 00xx (See Appendix A).

Keypad Type

The Keypad selection is for the Wedge NCR only. The selection is the calculator type of layout or
telephone layout. Both are shown in Figure 4-1.

Telephone

Calculator

Figure 4-1. Keypad Types

1

2

3

7

8

9

4

5

6

0

4

5

6

1

2

3

7

8

9

0