MagTek MINI MICR WEDGE User Manual

Page 30

Advertising
background image

MINI MICR WEDGE with 3-Track MSR

22


Fmt 01xx:
Parsed Text Format

FC0100

- Parsed text with dashes

FC0101

- Parsed text, replace dashes with “d”

Field Labels - TR-transit, AC-account #, CK-check #, AM-amount, TP-tpc,

EP-epc

Example:

-

PTTR444455556;AC

999-222-3;CK11045

Fmt 02xx: Parsed Text Format with Error Labels

FC0200

- Parsed text with dashes

FC0201

- Parsed text, replace dashes with “d”

Error Labels - PE-parsed error, NE-no error, TR-transit error,

CK-chk # error, TC-transit check digit error,

AM-amount error, OU-on us/account# error,

TP-tpc

error

Examples:

-

PTTR444455556;AC999-222-3;CK11045/PENE

- PTTR111?11111;AC123456/PETR (“?” = unreadable character)

Fmt 03xx: [acct

#]


[acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- keep spaces and dashes


Fmt 04xx: [acct

#]


[acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes


Fmt 05xx: [acct

#]


[acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- replace spaces and dashes with zeros


Fmt 06xx: [acct

#]


[acct #]:

- always xx characters, zero filled;

when xx=00 all characters are sent

- replace spaces and dashes with zeros


Fmt 07xx: [acct

#]


[acct #]:

- always xx characters, zero filled;

when xx=00 all characters are sent

- remove spaces and dashes


Fmt 08xx: [transit] [acct #]

[transit]:

- all characters in the field

-

keep

dashes


[acct #]:

- maximum of xx characters; when xx=00 all characters are sent

- remove spaces and dashes

Advertising