Chapter 2: installation, 1 built-in ethernet module, 2 user-installed ethernet module – Horner APG XL4 OCS HE-ETN300 User Manual

Page 11: Built-in ethernet module, User-installed ethernet module

Advertising
background image

SUP0740-07

CH.2

11/30/2009

Page 11 of 98

# 958

CHAPTER 2: INSTALLATION

2.1

Built-In Ethernet Module


As shown in Table 1.1 (page

7

), for some OCS Models, the SmartStack Ethernet Module is built-

in to the OCS unit, requiring no user-installation. For example, Figure 2.1 shows the location of
the RJ-45 Ethernet connector on OCS451, OCS551 and OCS651 units.

Ethernet Connector (OCS551 and OCS651) Ethernet Connector
(OCS451)








Figure 2-1 – SVGA Color Graphics OCS Bottom View

2.2

User-Installed Ethernet Module


For other OCS or RCS Models, the SmartStack Ethernet Module must be user-installed on the
back of the OCS / RCS unit. Figure 2.2 shows the locations of the Ethernet RJ-45 connector and
LED indicators on the user-installed SmartStack Ethernet Module.

Note: Normally, a user-installed Ethernet Module occupies the first I/O slot on the back of the

OCS or RCS unit. The only exception to this rule occurs if a FOX100 Module is also
installed. In this case, the FOX100 Module occupies the first I/O slot, and the Ethernet
Module is installed into the second I/O slot.






For more details on installing SmartStack I/O modules, refer to Chapter 2 of the Control Station
Hardware Manual (MAN0227), which also provides a handy checklist concerning panel box
layout and minimum clearance requirements.

Link & Activity LEDs

Ethernet Connector






Figure 2-2– User-Installed Ethernet Module Side View

Caution: For proper functioning and to avoid possible damage, do not install more than

four SmartStack Modules on the back of an OCS or RCS controller.

Advertising
This manual is related to the following products: