3 datalogger wiring (direct connection), Datalogger wiring (direct connection), 2. ground lug and power connectors on the avw200 – Campbell Scientific AVW200-series Vibrating Wire Interfaces User Manual

Page 28: 1. datalogger to avw200 cable options, N 4.3, N table 4-1

Advertising
background image

AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules

FIGURE 4-2. Ground Lug and Power Connectors on the AVW200

4.3 Datalogger Wiring (Direct Connection)

There are three options for connecting the AVW200 directly to the datalogger

(see TABLE 4-1); the cable is ordered as a common accessory.

TABLE 4-1. Datalogger to AVW200 Cable Options

Communication

Protocol

Cable Used

Datalogger Port for Cable Attachment

AVW200

Port for

Cable

Attachment

CR800,

CR850

CR1000,

CR3000

CR5000 CR10X CR23X

PakBus (direct

RS-232

connection)

18663 Null

Modem Cable

RS-232

RS-232

N/A

N/A

N/A

RS-232

PakBus (direct

RS-232

connection)

17855 or

SC110’s DTE

Cable (pigtail to

DB9; see

TABLE 4-2)

Control

port pair

(C1/C2

or

C3/C4)

Control

port pair

(C1/C2,

C3/C4,

C5/C6, or

C7/C8)

N/A

N/A

N/A

RS-232

SDI-12

CABLE3CBL-L

Cable

C1 or

C3

and G

C1, C3,

C5,

or C7

and G

SDI12

and

G

C1

through

C8 and

G

C5

through

C8 and

G

C1 and G

Connects to a power source via

19246 power cable

Connects to earth ground via an 8 AWG wire

when not directly connected to a datalogger

Indicates AVW200 is

connected to a power source

20