Campbell Scientific CR23X Micrologger User Manual
Page 264

APPENDIX B. CONTROL PORT SERIAL I/O INSTRUCTION 15
B-20
31:
Z=X*F (P37)
1:
38
X Loc [ RAW_SPDK ]
2:
0.6214
F
3:
13
Z Loc [ SPD_MPH ]
; OUTPUT DATA EVERY INTERVAL
32:
Do (P86)
1:
10
Set Output Flag High (Flag 0)
33:
Real Time (P77)
1:
1220
Year,Day,Hour/Minute (midnight = 2400)
34:
Resolution (P78)
1:
1
High Resolution
35:
Sample (P70)
1:
13
Reps
2:
1
Loc [ HOUR_MIN ]
; SET DATALOGGER CLOCK WHEN VALID TIME AND GPS IS AVAILABLE EVERY INTERVAL
36:
If Flag/Port (P91)
1:
28
Do if Flag 8 is Low
2:
30
Then Do
37:
Do (P86)
1:
18
Set Flag 8 High
38:
Z=X*F (P37)
1:
1
X Loc [ HOUR_MIN ]
2:
0.01
F
3:
39
Z Loc [ HOURS ]
39:
Z=INT(X) (P45)
1:
39
X Loc [ HOURS ]
2:
39
Z Loc [ HOURS ]
40:
Z=X*F (P37)
1:
1
X Loc [ HOUR_MIN ]
2:
0.01
F
3:
40
Z Loc [ MINUTES__ ]
41:
Z=FRAC(X) (P44)
1:
40
X Loc [ MINUTES__ ]
2:
40
Z Loc [ MINUTES__ ]
42:
Z=X*F (P37)
1:
40
X Loc [ MINUTES__ ]
2:
100
F
3:
40
Z Loc [ MINUTES__ ]
43:
Z=X (P31)
1:
2
X Loc [ SECONDS ]
2:
41
Z Loc [ SEC ]