Campbell Scientific CR23X Micrologger User Manual
Page 288

APPENDIX G. CALLBACK (CR23X INITIATED TELECOMMUNICATIONS)
G-6
8: If Flag/Port (P91) ;Enable Cell Transceiver if No Alarm
1:
11
Do if Flag 1 is High
2:
30
Then Do
9: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
41
Set Port 1 High
10: If time is (P92)
1:
10
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
51
Set Port 1 Low
11: End (P95)
12: If Flag/Port (P91) ;Enable Cell Transceiver if Alarm
1:
21
Do if Flag 1 is Low
2:
30
Then Do
13: Do (P86)
1:
41
Set Port 1 High
14: End (P95)
;*****************************************************
15: Initiate Telecommunications (P97)
1:
21
Phone Modem/1200 Baud<<<<<<<<<<<Note Device / Baud Code
2:
1
Disabled when User Flag 1 is High
3:
120
Seconds Call Time Limit
4:
0
Seconds Before Fast Retry
5:
0
Fast Retries
6:
0
Minutes before Slow Retry
7:
3
Failures Loc [ Failures ]
8:
123
Call-back ID
16: Extended Parameters 4 Digit (P68)
1:
1
Option
; First Digit of Computer's Phone Number
2:
4
Option
3:
3
Option
4:
5
Option
5:
1
Option
6:
2
Option
7:
3
Option
8:
4
Option
17: Extended Parameters 4 Digit (P68)
1:
5
Option
2:
6
Option
3:
7
Option
4:
13
Option
; ASCII Decimal Termination Character
5:
0
Option
6:
0
Option
7:
0
Option
8:
0
Option