Campbell Scientific CR23X Micrologger User Manual
Page 62

SECTION 3. INSTRUCTION SET BASICS
3-8
TABLE 3.9-3. CR23X Output Instructions R = No. of Reps.
FINAL
INTER.
MEMORY
FLAG O
FLAG 0
INSTRUCTION
LOC.
VALUES
BYTES
OPTION
LOW
HIGH
69 WIND VECTOR
2+9R
2R
12
00,
2.7+8.3R
3.9+38.7R
3R
01,
2.7+8.3R
4.5+15.6R
4R
02,
2.4+8.8R
3.8+34.7R
2R
10,
2.1+8.2R
0.0+27.3R
3R
11,
2.1+8.2R
3.7+15.8R
4R
12,
1.6+6.4R
3.1+27.4R
70 SAMPLE
0
R
6
0.1
0.5+0.2R
71 AVERAGE
1+R
R
7
0.6+0.3R
1.4+1.7R
72 TOTALIZE
R
R
7
0.4+0.3R
0.9+0.6R
73 MAXIMUM
1R
R
8
0,
0.6+0.5R
1.6+1.4R
2R
2R, 3R
01,10,11
0.6+0.5R
1.6+2.8R
74 MINIMUM
1R
R
8
0,
0.6+0.5R
1.6+1.4R
2R
2R, 3R
01,10,11
0.6+0.5R
1.6+2.8R
75 HISTOGRAM
1+bins
∗
R
BINS*R
24
0.7+1.7R
0.8+(2.8+0.7*BIN)R
77 REAL TIME
0
1 TO 4
4
0.1
2.2
78 RESOLUTION
0
0
3
0.4
0.4
79 SMPL ON MM
R
R
7
0.2
0.7+0.3R
80 STORE AREA
1
0
0
7
0.2
0.2
81 RAINFLOW HIST see
instruction
42
82 STD. DEV.
1+3R
R
7
0.8+1.0R
3.3+7.0R
TABLE 3.9-4. Program Control Instruction Memory and Execution Times
MEMORY
INTER.
PROG.
INSTRUCTION
LOC.
BYTES
EXECUTION TIME (ms)
83 IF CASE <F
0
10
0.23
85 LABEL SUBR.
0
3
0.08
86 DO
0
6
0.17
87 LOOP
1
10
0.16
88 IF X<=>Y
0
11
0.42
89 IF X<=>F
0
13
0.32
90 LOOP INDEX
0
3
0.40
91 IF FLAG/PORT
0
7
0.22
92 IF TIME
1
12
0.21
93 BEGIN CASE
1
8
0.16
94 ELSE
0
4
0.16
95 END
0
4
0.22
96 SERIAL OUT
0
3
97 INIT.TELE.
7
17
98 SEND CHAR.
0
3
120 GOES SAT
0 or 2
5
121 ARGOS SAT
0
8