Campbell Scientific CR23X Micrologger User Manual
Page 286

APPENDIX G. CALLBACK (CR23X INITIATED TELECOMMUNICATIONS)
G-4
*Table 1 Program
01:
10
Execution Interval (seconds)
1: Panel Temperature (P17)
1:
1
Loc [ RefTemp ]
2: Thermocouple Temp (DIFF) (P14)
1:
1
Reps
2:
11
10 mV, Fast Range
3:
5
DIFF Channel
4:
1
Type T (Copper-Constantan)
5:
1
Ref Temp (Deg. C) Loc [ RefTemp ]
6:
2
Loc [ TempDegC ]
7:
1.0
Mult
8:
0
Offset
3: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
1
Interval (same units as above)
3:
10
Set Output Flag High (Flag 0)
4: Real Time (P77)
1:
1220
Year,Day,Hour/Minute (midnight = 2400)
5: Average (P71)
1:
1
Reps
2:
2
Loc [ TempDegC ]
6: If (X<=>F) (P89)
1:
2
X Loc [ TempDegC ]
2:
4
<
3:
31
F
4:
11
Set Flag 1 High
7: If (X<=>F) (P89)
1:
2
X Loc [ TempDegC ]
2:
3
>=
3:
32
F
4:
21
Set Flag 1 Low
8: Initiate Telecommunications (P97)
1:
11
Direct CS IO/1200 Baud<<<<<<<<<<<Note Device / Baud Code
2:
1
Disabled when User Flag 1 is High
3:
120
Seconds Call Time Limit
4:
0
Seconds Before Fast Retry
5:
0
Fast Retries
6:
0
Minutes before Slow Retry
7:
3
Failures Loc [ Failures ]
8:
123
Call-back ID