4 full/half duplex, 5 setting powerup options, 6 setting display contrast – Campbell Scientific CR23X Micrologger User Manual

Page 48: 7 set initial baud / set rs232 power

Advertising
background image

SECTION 1. FUNCTIONAL MODES

1-14

1.8.4 FULL/HALF DUPLEX

The

D

Mode can also be used to set

communications to full or half duplex. The default
is full duplex, which works best in most situations.

TABLE 1.8-7. Setting Duplex

Key entry

Display

D

13: Enter Command
00

9

A

09: Comm Duplex
0x

If x=0 the CR23X is set for full duplex.
If x=1 the CR23X is set for half duplex.

You may now change the option:

0

A

Set full duplex

1

A

Set half duplex

1.8.5 SETTING POWERUP OPTIONS

Setting options for the Program on Powerup
allows the user to specify what information to
retain from when the datalogger was last on.
This allows Flag/Port status, the User Timer,
and the Input/Intermediate Storage to be
cleared or not cleared.

Table 1.8-8. Setting Powerup Options

Key entry

Display

D

13: Enter Command
00

1

0

A

10: Power Up Option
0X

Where X is the powerup option currently
selected. You may now change the option:

0

A

Clears input locations, ports, flags,
user timer, and intermediate storage
locations.

1

A

Clears intermediate storage only
(leaves Input Storage, Flags/Ports, and
User Timer as is).

2

A

Doesn’t clear anything.

1.8.6 SETTING DISPLAY CONTRAST

The CR23X automatically adjusts the LCD
display contrast for temperature within two
seconds after power-up. If necessary, the user
can fine tune the default contrast in the

D

mode. The user entered adjustment is valid
only for the specific temperature range wherein
the adjustment was made. If the CR23X
temperature moves out of that range, the
default setting for the next range controls the
contrast. See “Telecommunications” R
command information on changing default
settings in each temperature range.

TABLE 1.8-9.

Key
Entry

Display

Comments

D

13: Enter Command
00

1

1

A

11: Program Stopped
11: Dsply Contrast
xxxx

xxxx is the
current setting.
Key in new
setting followed
by an A or . . .

A

11: D Dark C Light
xxxx

Press A to
darken, B to
lighten

0

LOG

Save setting,
restart program

1.8.7 SET INITIAL BAUD / SET RS232 POWER

Table 1.8-11 shows the option codes available
for setting the initial baud rate. Setting the initial
baud rate forces the CR23X to try the selected
baud rate first when connecting with a device.
By indexing the option, the “Computer RS232”
port can be powered up. Power up of the
RS232 port puts 9 volts on pins 1 (DTR) and 8
(RTS), and 8 volts on pin 2 (TX).

Advertising