Campbell Scientific CR23X Micrologger User Manual
Page 292

APPENDIX G. CALLBACK (CR23X INITIATED TELECOMMUNICATIONS)
G-10
30: Z=F (P30)
1:
0
F
2:
0
Exponent of 10
3:
8
Z Loc [ cntr_set ]
31: Z=F (P30)
1:
0
F
2:
0
Exponent of 10
3:
9
Z Loc [ CallCntr ]
32: Do (P86)
1:
28
Set Flag 8 Low
33: End (P95)
34: IF (X<=>F) (P89)
1:
8
X Loc [ cntr_set ]
2:
1
=
3:
1
F
4:
30
Then Do
35: Z=Z+1 (P32)
1:
9
Z Loc [ CallCntr ]
36: End (P95)
37: Initiate Telecommunications (P97)
1:
21
Phone Modem/1200 Baud
2:
4
Disabled when User Flag 4 is High
3:
30
Seconds Call Time Limit
4:
0
Seconds Before Fast Retry
5:
0
Fast Retries
6:
15
Minutes before Slow Retry
7:
4
Failures Loc [ ErrorLoc ]
8:
0
Data Logger ID
38: Extended Parameters (P63)
1:
1
Option
; ASCII digit, first digit in pager number
2:
8
Option
3:
0
Option
4:
1
Option
5:
7
Option
6:
5
Option
7:
0
Option
8:
9
Option
39: Extended Parameters (P63)
1:
5
Option
2:
3
Option
3:
4
Option
; Last digit in pager number
4:
44
Option
; ASCII Decimal Equivalent Comma (2 second
delay)
5:
44
Option
6:
44
Option
7:
9
Option
; ASCII digit, first digit in pager message
8:
8
Option