SECTION 9. INPUT/OUTPUT INSTRUCTIONS

9-11

PARAM.

DATA

NUMBER

TYPE

DESCRIPTION

01:

2

Repetitions Hit C (--) to
skip repeat of
excitation

02:

2

Single-ended channel
for first measurement

03:

2

Excitation Channel

04:

2

Start frequency of
sweep (100'S of Hz)

05:

2

End frequency of
sweep (100'S of Hz)

06:

4

# Cycles to measure (0
means none)

07:

4

Delay before excitation
applied (0.01 sec units)

08:

4

Input location (1/T

2

), T

in ms

09:

FP

Multiplier

10:

FP

Offset

Input locations altered: 1 per repetition

*** 29 INW PS9105E ***

FUNCTION
The Instrumentation Northwest PS9105
Enhanced Pressure Transducer is used to
measure water level. This instruction excites
the PS9105 with a single excitation channel and
measures the sensor’s output on two
consecutive differential analog input channels.
The pressure and sensor temperature are
written into two consecutive input locations
starting at the location specified in parameter 3.

Each PS9105 has 20 enhanced measurement
parameters that are documented on the
calibration sheet. Enter these parameters into
Instruction 29.

PARAM.

DATA

NUMBER

TYPE

DESCRIPTION

01:

2

Differential channel
number for first
measurement

02:

2

Excitation channel
number

03:

4

Input location number

04:

FP

Pressure Range (psig)
(enh. par. 1)

05:

FP

Enhanced Parameter 2

06:

FP

Enhanced Parameter 3

07:

FP

Enhanced Parameter 4

08:

FP

Enhanced Parameter 5

09:

FP

Enhanced Parameter 6

10:

FP

Enhanced Parameter 7

11:

FP

Enhanced Parameter 8

12:

FP

Enhanced Parameter 9

13:

FP

Enhanced Parameter 10

14:

FP

Enhanced Parameter 11

15:

FP

Enhanced Parameter 12

16:

FP

Enhanced Parameter 13

17:

FP

Enhanced Parameter 14

18:

FP

Enhanced Parameter 15

19:

FP

Enhanced Parameter 16

20:

FP

Enhanced Parameter 17

21:

FP

Enhanced Parameter 18

22:

FP

Enhanced Parameter 19

23:

FP

Enhanced Parameter 20

Input location altered: 2

*** 105 SDI-12 RECORDER ***

NOTE: Version 1.2 of the SDI-12
specification has been implemented in the
CR10X. Features added in this version are
marked with a dagger (†) and may not be
supported by older SDI-12 sensors.

Instruction 105 allows data to be collected from
SDI-12 sensors. The sensor’s SDI-12 data line
is connected to a control port (C1 or C2). The
SDI-12 ground should be connected to a "G"
terminal on the CR10X wiring panel. SDI-12
power may be connected to 12V.

If multiple SDI-12 sensors are used, up to ten
sensors may be connected to a single control
port, but each sensor must have a unique
address and requires a separate Instruction
105.

PARAM.

DATA

NUMBER

TYPE

DESCRIPTION

01:

4

Address (0-9, †10-
126)

02:

2

Command (Table 9-8)

03:

2

Control Port (C1-C8)

04:

4

Input Loc.

05:

FP

Mult

06:

FP

Offset

Input locations altered: 1-9 (†1-99), depending
on the SDI-12 sensor

Intermediate locations required: 21