Interface Specifications B-7

B.3 RS-232 Serial Interface

Data Transfer Rates (Baud Rate ):

110

2400

300

4800

600

9600

1200

19200

1800

Synchronization:

Start-Stop Bits

Data Format:

Start Bit:

1

Data Bits:

7 or 8

Parity:

Odd, even or no parity

Stop Bit:

1 for reception

1 for transmission

If the host serial interface is configured for 7 Bit data with no parity, data from host
computer must contain two stop bits.

Handshaking Protocols:

X-ON/X-OFF: (DC1/DC3) In this protocol, the printer will respond with the DC3 (X-

OFF) character when:

Print buffer is nearly full.
Paper out condition exists.
Carriage jam condition detected.
Printer is off line.