User’s Guide

H-2 Transparency Mode

The DGCL Recognition feature gives the user the ability to enable and disable recognition of
the Datasouth Graphics Command Language. When the feature is ‘enabled’, the DGCL
entrance command ‘^PY’ will be recognized and executed thus giving the user access to all
the DGCL commands. When the feature is ‘disabled’, the DGCL entrance command ‘^PY’
will be ignored thus locking out user access to the DGCL mode. Under this condition all
DGCL data will be passed on to the active emulation mode command processor and handled
in a manner consistent with that active emulation mode.

The ‘Default Command Character’ feature gives the user the ability to select the default
command character for the DGCL mode. The command character is the leading character in
any valid DGCL command sequence. Valid selectable command characters would be any
printable ASCII code between 33 and 255.

The ‘One Dot Barcode Overlap’ feature will give the user the ability to overlap the different
passes of a barcode symbol by one dot.

The ‘DGCL Exit Mode’ feature gives the user the ability to select 1 of 4 exit modes.

NOTE

The up caret character (^) is the command

character used to introduce a DGCL
command sequence and does not represent
the control key. This character cannot be
printed in DGCL mode unless you change the
command character with the ^N command.
The default value of the command character
is determined by the ‘Default Command

Character’ feature. It will be assumed
throughout the remainder of this
specification, that the default command
character is the ‘^’ character.