Interface Specifications B-9

SIGNAL

P/N

NO MODEM CONTROL

MODEM CONTROL

DTR

20

11

When the printer is ready to

accept data, this line will be high
(+EIA LEVEL). This line will go
low (-EIA LEVEL) when:

a. Print buffer is nearly full

(within 512 bytes)

b. Paper out condition exists.

c. Carriage jam condition

detected.

d. Printer is off line.

When the printer is ready to

accept data, this line will be high
(+EIA LEVEL). This line will go
low (-EIA LEVEL) when:

a. Print buffer is nearly full

(within 512 bytes)

b. Paper out condition exists.

c. Carriage jam condition

detected.

d. Printer is off line.

RTS

4

This signal will always be held
high

RTS will be held high when the
interface is ready to transmit data.

CTS

5

CTS is always assumed high

The interface will monitor the
CTS signal generated by the host
in response to RTS. When this
signal goes on (high), the host is
ready to receive data.

DSR

6

DSR is always assumed high

If DSR is low, the interface will
ignore all data received on the
serial port. This signal must hold
high for the interface to receive
and transmit data.

DCD

8

Same as DSR

Same as DSR