Enable log output, Alliedware plus command – Allied Telesis AT-S63 User Manual
Page 316

Chapter 17: Event Log and Syslog Client Commands
316
Section II: Advanced Operations
ENABLE LOG OUTPUT
Syntax
enable log output[=
output-id
]
Parameters
output
Specifies the output definition ID number to enable.
The range is 2 to 20.
Description
This command enables an output definition that was disabled using
“DISABLE LOG OUTPUT” on page 313.
Example
The following command enables output definition number 4:
enable log output=4
The following command enables all output definitions:
enable log output
AlliedWare Plus
Command
Syntax
log enable
output-id
Mode
Configure mode
Description
This AlliedWare Plus command is equivalent to the standard command.
Example
This command enables output definition number 2:
awplus> enable
awplus# configure terminal
awplus(config)# log enable 2
Command
Available
AlliedWare Plus