AMX NI-2100/3100/4100 User Manual

Page 53

Advertising
background image

WebConsole - System Options

45

NI Series WebConsole & Programming Guide

6.

In the Command and String fields, enter any character strings that can be sent as either a String or
Command, and press Send to transmit to the Master.

When entering a Send Command, do not include the "send c" or "send_command" in the
statement - only type what would normally occur within the quotes (but don't include the
quotes either).

For example to send the "CALIBRATE" send command, type CALIBRATE (no quotes)
rather than SEND_COMMAND <dev> "CALIBRATE".

String Expressions start and end with double quotes (" "). Double quotes are not escaped,
rather they are embedded within single quotes. String expressions may contain string literals,
decimal numbers, ASCII characters and hexadecimal numbers (prepended with a $), and are
comma-delimited.

String Literals start and end with single quotes ('). To escape a single quote, use three single
quotes (''').

Level Data Type Minimum Value Maximum Value
CHAR

0

255

INTEGER

0

65535

SINTEGER

-32768

32767

LONG

0

429497295

SLONG

-2147483648

2147483647

FLOAT

-3.402823466e+38 3.402823466e+38