UFL-420/440 WATER FILTRATION SYSTEM

11

P/N 1011055 Rev. F 12/13

INSTALLATION (continued)

Mounting the System

The UFL system comes with a Mounting Bracket to

mount the system securely. When mounting the system,

pay attention to the following guidelines:

• Note the location of the water supply, drain, and

an appropriate electrical outlet when choosing a

mounting location.

• Allow sufficient access for cartridge replacement.

The UFL-420 system should be mounted with 20

inches below the unit to allow proper access when

changing cartridges. The UFL-440 system should

be mounted with 40 inches below the unit.

• Mount the system near but NOT above an appropri-

ate electrical outlet.

• Do NOT mount the system above any electrical

equipment or items that may be damaged if they

get wet.

• Mount the system near a drain for flushing opera-

tions.

• Mount the system before all consumable water

filtration processes.

• Secure the Mounting Brackets into wall studs or

with the appropriate heavy duty mounting hardware.

The system is pre-assembled to Mounting Brackets.

The Mounting Brackets have mounting holes secure the

bottom of the system to the wall.

Filter

Base

Flow Control

(supplied,

see inset)

Inlet Drain

Valve (not

Supplied)

Sanitation

Plug (not

supplied)

Inlet Water

Valve (not

supplied)

Incoming

Water

Supply

Figure 3. Inlet Water Plumbing

Flow Controller

Into

Filter

Base

INSET

Water Flow

Inlet Water Plumbing

The Inlet water plumbing line should be 1” NPT or

larger. A shutoff valve (not supplied) should be installed

in the line leading to the system. The valve should be

mounted close to the system inlet and sized properly for

the inlet plumbing line.
An optional “T” or Cross Fitting with cap or plug can be

installed between the Inlet Valve and the System Inlet.

This fitting can be used for draining and sanitizing the

system and downstream plumbing.
The system should only be connected to the cold water

line.
Before connecting the fitting to the System Inlet, the

plumbing to the system must be flushed clear of all

debris. Hold a bucket at the inlet water line and slowly

open the Inlet Water Valve. Allow the pipe to flush until

all debris is removed.

Advertising