Sanitizing the System and Lines

The plumbing must be sanitized to eliminate possible

contamination that may have occurred during the instal-

lation process.
One ounce (30 ml) of liquid chlorine bleach (regular

bleach, unscented 5.25 % - 6 % sodium hypochlo-

rite) or Kay-5 sanitizer solution (Sodium Dichloro-s-

Triazinetrione Dihydrate, 6%) or equivalent can be used

to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a

1 oz. packet of Kay-5 powder in 2 oz. (60 ml) of clean

warm water. This can be done by removing 1 inch from

the top of the Kay-5 packet and adding the 2 oz. of

warm water to the packet. Mix with a coffee stirrer to

dissolve. When added to the system, this will create a

60-100 ppm chlorine solution.
NOTE: Follow the handling and safety instructions

supplied with the sanitizer.
1. Follow the steps in the

Rinsing the Ultra Filter

Cartridge in the Installation section of this manu-

al.

2. Turn off the water to the system.
3. Open the faucet or tap closest downstream to the

system.

4. Close the Inlet Water Valve and allow the system

to depressurize.

5. Place a bucket under the “T” or cross fitting at

the inlet connection to the system. Open the inlet

drain valve or unscrew the cap to drain the sys-

tem.

6. Press the

FLUSH button to help drain the system.

7. When the water flow out of the inlet fitting stops,

close the inlet drain valve and pour the liquid

bleach into the inlet connection fitting. Be careful

not to spill sanitizer onto clothing or skin. You may

want to add the sanitizer using a cup. Reattach

the cap on the fitting.

8. Slowly open the inlet water valve and allow water

to flow out of the tap until the smell of sanitizer is

present.

CAUTION

Ingesting the protective solution may cause irrita-

tion of the gastrointestinal tract, colic, diarrhea, or

other similar symptoms

IMPORTANT

Commonwealth of Massachusetts Plumbing Code

248 CMR shall be adhered to. The use of saddle

valves are not permitted, please consult your

local plumber.

9. Immediately close the tap and let the system

stand with no water flow for at least 15 minutes to

allow the sanitizer to sanitize the pipes.

10. After 15 minutes without water flow, open the tap

and flush until the presence of sanitizer is gone.

All other taps should be opened to flush any

bleach from the plumbing. Close the taps.

11. Press the

FLUSH button to complete the flushing

process.