Performance data sheet, Filter cartridge capacities, Performance claims for percent reduction – A.J. Antunes & Co UFL-440 9700475 User Manual

Page 8

Advertising
background image

UFL-420/440 WATER FILTRATION SYSTEM

8

P/N 1011055 Rev. F 12/13

PERFORMANCE DATA SHEET

Filter Cartridge Capacities

Maximum Operating Pressure

100 psig (690 kPa)

Maximum Operating Temperature

100°F (38°C)

Minimum Operating Temperature

40°F (4°C)

Maximum Trans Membrane Pressure 45 PSI (3.1 Bar)

pH Range

3-10

MWCO

100 kD

NSF/WQA Certified Rated

Service flow:
UFL-420

7.9 gpm (30 l/m)

UFL-440

13 gpm (49 l/m)

This system has been tested according to NSF/ANSI

Standard 42 and 53 for reduction of the substances

listed below. The concentration of the indicated sub-

stances in water entering the system was reduced to a

concentration less than or equal to the permissible limit

for water leaving the system, as specified in NSF/ANSI

42 or 53. While testing was performed under standard

laboratory conditions, actual performance may vary.

Performance Claims for Percent Reduction

Substance

Influent

Challenge

Concentration

Reduction

Requirement

Minimum

%

Reduction

cyst

1

minimum

50,000/L

99.95%

99.95%

Turbidity

11 ± 1 NTU

≤ 0.5 NTU

99.1%

Particulate Class I

Particles 0.5 to <

1µm

at least 10,000

particles /mL

≥ 85%

N/A

1based on the use of microspheres or Cryptosporium parvum oocysts

NOTE: The NSF/WQA information provided applies

to the Ultra Filter cartridge.

Do not use with water that is microbiologically

unsafe or of unknown quality without adequate dis-

infection before or after the system. Systems certi-

fied for cyst reduction may be used on disinfected

waters that may contain filterable cysts.

System Tested and Certified by NSF

International and WQA against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction & Turbidity Reduction

as verified and substantiated by test data.

System Tested and Certified by WQA

against NSF/ANSI Standard 372

for lead-free compliance