Installation (continued) – A.J. Antunes & Co UFL-440 9700475 User Manual

Page 13

Advertising
background image

UFL-420/440 WATER FILTRATION SYSTEM

13

P/N 1011055 Rev. F 12/13

INSTALLATION (continued)

Starting the Controller

1. Select the proper AC plug for your electrical outlet

and install it onto the power supply.

2. Plug the appropriate end of the power cord into

the controller.

3. Plug the other end of the power cord into the elec-

trical outlet. The LEDs on the controller will light

up.

4. The controller automatically enters Flush Mode

and the Flush LED starts to flash.

5. When flushing is complete, the Flush LED will

stop flashing and one or more LEDs will remain lit,

indicating the unit has power and which interval is

selected in the controller.

Rinsing the Ultra Filter Cartridge

The Ultra Filter Cartridge must be rinsed before the sys-

tem is used to remove any air and protective solution.
NOTE: Ultra Filter Cartridge must be rinsed to drain

before use. Rinsing to drain removes storage solu-

tion and air. Do NOT rinse into carbon if present.

Carbon life and/or performance may be affected.

1. Direct water from the Permeate Outlet to a drain.
2. Open the tap or faucet closest downstream to the

filter system.

3. Slowly open the inlet water valve and allow water

to enter the system.

4. Press the

FLUSH button. The Drain Valve will

open and air and water will come out of the drain

line. Repeat six times to ensure all air and stor-

age solution are flushed out of the Ultra Filter

Cartridge.

5. Allow water to continue to run through the system

and out the faucet for 15 minutes.

6. Inspect the unit for any leaks and repair as

needed.

7. After 15 minutes with water flow, close the tap or

faucet and let the system stand without water flow

for 15 minutes to allow trapped air to come out of

the hollow fibers of the Ultra Filter Cartridge.

8. After 15 minutes without water flow, open the tap

or faucet for five minutes to flush out the trapped

air.

9. Close the tap or faucet.
10. Press the

FLUSH button to open the Drain Valve.

Repeat six times to ensure any remaining air is

flushed out of the system.

Advertising