UFL-420/440 WATER FILTRATION SYSTEM

5

P/N 1011055 Rev. F 12/13

IMPORTANT SAFETY INFORMATION

Protect from becoming dry
If the membrane dries out, irreversible damage to the

Ultra Filter membrane may result. Protect the filter from

becoming dry by keeping it wet and sealed at all times.
Protect from freezing
If the Ultra Filter membrane freezes during operation

or storage, irreversible damage to the membrane and

brittle cracking of the cartridge or housing may result.
Protect from direct sunlight or other UV sources
Avoid long-term exposure to direct sunlight or other UV

sources. The Ultra Filter should be stored in a dark

location.
Protect from high temperatures or abrupt variation

in temperature
The maximum operating temperature is 100°F (38°C).

Avoid abrupt variations in temperature. Any temperature

variation should be made slowly.
Protect from rough handling or dropping
Mechanical damage, external breakage, and/or internal

breakage of the filter can result if the system is dropped

or bumped. Handle with care at all times during trans-

portation and installation.
Protect from organic solvents and concentrated

acids
Prevent any and all contact of the membrane with

strong solvents, solvents containing chlorine, or con-

centrated acids. Do NOT use strong solvents or con-

centrated acids on any plastic parts of the filter system.

Examples of some solvents to avoid: acetone, methyl

acetate (nail polish remover); hexane (spot removers);

turpentine, toluene (paint thinners); dry cleaning solu-

tions, insecticides.
Protect from abrasive material
The membranes must be protected from abrasive

materials like shavings left in a pipe. Abrasive materials

in contact with the membrane can cause irreversible

damage to the membrane. All pipes must be flushed

clean before installing the filter. All plastic parts of the

filter system must be protected from sharp objects like

knives, sand paper, or other tools. Cutting or nicking a

plastic part can weaken it and cause a leak. Do NOT

use abrasive cleansers on any plastic parts.
Protect from water hammer
The system must be protected from shock, pressure

surges, or pulsation that may occur inside water pipes.

Water hammer occurs in pipes when a valve or faucet

shuts quickly. Install a water hammer arrestor (pressure

vessel containing compressed air separated from the

water by a diaphragm) to reduce pressure shock.

CAUTION

This equipment is to be installed to comply with

the basic plumbing code of the Building Officials

and Code Administrators, Inc. (BOCA) and the

Food Service Sanitation Manual of the Food and

Drug Administration (FDA).

CAUTION

All electrical connections must be in accordance

with local electrical codes and any other appli-

cable codes.

A ground fault circuit interrupter (GFCI) must be

installed on the circuit to this system.

When installed on metallic plumbing, a properly

sized electrical bonding jumper must be installed

across the inlet and outlet pipes serving this unit.

CAUTION

Water Flow Regulator Assemblies are NOT inter-

changeable. Operating the system with the wrong

Water Flow Regulator or without a regulator can

damage the system, cause personal injury, and

voids the warranty!