UFL-420/440 WATER FILTRATION SYSTEM

4

P/N 1011055 Rev. F 12/13

IMPORTANT SAFETY INFORMATION

In addition to the warnings and cautions in this manual,

use the following guidelines to safely operate the sys-

tem:

• Read all instructions before using equipment.

• Install or locate the equipment only for its intend-

ed use as described in this manual.

• Do NOT use corrosive chemicals in this equip-

ment.

• Do NOT operate this equipment if it has a dam-

aged cord or plug; if it is not working properly, or if

it has been damaged or dropped.

• This equipment should be serviced by qualified

personnel only. Contact A.J. Antunes & Co. for

repair.

• Do NOT immerse cord or plug in water.

• Keep cord away from heated surfaces.

• This equipment should be supplied with only cold

water.

• For installations in Massachusetts, the

Commonwealth of Massachusetts Plumbing Code

248 CMR shall be adhered to. The use of saddle

valves are not permitted. Please consult your local

plumber.

The following warnings and cautions appear throughout

this manual and should be carefully observed.

• Unplug the power cord before performing any

service or maintenance on the unit.

• All electrical connections must be in accordance

with local electrical codes and any other appli-

cable codes.

WARNING ELECTRICAL SHOCK HAZARD.

FAILURE TO FOLLOW THESE INSTRUCTIONS

COULD RESULT IN SERIOUS INJURY OR

DEATH.

- Do NOT modify the power supply cord plug. If

it does not fit the outlet, have a proper outlet

installed by a qualified electrician.

- Do NOT use an extension cord with this unit.

• If the supply cord is damaged, it must be replaced

by the manufacturer, its service agent, or a simi-

larly qualified person.

• This equipment is to be installed to comply with

the local plumbing code and any other applicable

code.

• Water pressure must not exceed 100 psig (690

kPa). To reduce water pressure, install a water

pressure regulator and set to suit the application.

• The trans membrane pressure (inlet pressure

minus the permeate water pressure) must not

exceed 45 psi (310 kPa).

• A ground fault circuit interrupter (GFCI) must be

installed on the circuit to this system.

• When installed on metallic plumbing, a properly

sized electrical bonding jumper must be installed

across the inlet and outlet pipes serving this unit.

NOTE: If the inlet water pressure is less than 50

psig (345 kPa), it is recommended that a suitably-

sized booster system (outlet pressure 60 psig - 100

psig max (414 kPa - 690 kPa max) be installed.