Maintenance – A.J. Antunes & Co UFL-440 9700475 User Manual

Page 15

Advertising
background image

UFL-420/440 WATER FILTRATION SYSTEM

15

P/N 1011055 Rev. F 12/13

MAINTENANCE

System Sanitization

The system and downstream plumbing should be sani-

tized at least every six months. When necessary, follow

the procedure in

Sanitizing the System and Lines in

the Installation section of this manual.

Replacing the Ultra Filter Cartridge

1. Turn off water to the system by closing the inlet

valve.

2. Press the

FLUSH button to flush the system and

relieve pressure. Repeat several times.

3. Place a bucket under the “T” or cross fitting at the

inlet connection to the system. Open the valve or

unscrew the cap to drain the system.

NOTE: Make sure there is enough room next to the

system to remove the cartridge.

4. Close the inlet drain valve or reattach the cap on

the “T” fitting when the water flow stops.

5. Unplug the system.

6. Remove the Snap Ring from the Ultra Filter

Housing. Grab the raised lug with a pair of pliers

and pull towards the center of the End Cap and

away. The Snap Ring should lift out of its groove.

7. Remove the End Cap, End Cap O-ring, and

Cartridge from the housing (Figure 5).

NOTE: If the Cartridge does not easily come out

of the Housing, remove the opposite End Cap for

assistance.

8. Inspect the Large End Cap O-rings and End Cap

O-ring for nicks or cuts. Replace as needed.

9. Lubricate all O-rings with a food-grade silicone

lubricant. Apply a light coating of lubricant to the

inside center tube at both ends of the new car-

tridge.

10. Record the serial number of the new cartridge.

The cartridge serial number is engraved on one

end of the outer tube (for example: 05K 12013).

11. Install the End Cap O-ring on the End Cap and

insert the Large End Cap into the end of the new

cartridge.

12. Position the new cartridge and End Cap at the

housing and gently insert into the housing.

13. Press the End Cap into position until it is fully

seated and the Snap Ring groove is visible.

14. Install the Snap Ring by guiding the non-lugged

end into the groove first, pushing outward and

working around the ring until it snaps into place.

NOTE: Make sure that the Snap Ring is fully seated

before turning the water on.

15. Rinse the new Ultra Filter Cartridge before

placing the system back into operation. Follow

the

Rinsing the Ultra Filter Cartridge and

Sanitizing the System and Lines procedures in

the Installation section of this manual to complete

the cartridge change.

16. When rinsing is complete, repressurize the

system.

Figure 5. Replacing the Ultra Filter Cartridge

Ultra Filter

Cartridge

End Cap

O-Rings

End Cap

Snap Ring

Cartridge

O-Ring

Advertising