Configuring SNMP Event Notification Types

183

The following table lists the system events and their associated Event
Classes. For more information about Event Classes, refer to Chapter 10,
Managing System Events, on page 203.

Table 9-7 List of System Events

E

System Event

Description

Event Class

Cluster events:

Cluster events refer to faults that affect
the management module.

authentication-failure

SNMP receives a bad Community Name.

Notice

bcm-failover-down

Services are going down. This notification
type applies to redundant configurations
only.

Notice

bcm-failover-up

Services are coming up. This notification
type applies to redundant configurations
only.

Notice

bcm-state-change

A change in the craft port IP address.

Notice

bcm-sw-mismatch

The secondary will not come up because
its software revision does not match the
software revision of the primary.

Notice

trace-log

For ADC internal use only.

Notice

cold-start

Generated when module boots from
power up.

Notice

warm-start

Generated when module boots from reset. Notice

icl-state-change

A change in the ICL link.

Notice

Module events:

Module events refer to hardware faults
that affect any application module.

cable-modem-auth-failure

Cable modem failed authorization and did
not register.

Notice

cable-modem-down

Cable modem is not operational.

Critical

cable-modem-up

Cable modem is operational.

Notice

card-down

Application module failure.

Critical

card-up

Application module is operational.

Notice

dhcp-relay-not-configured

DHCP configuration error.

Warning

local-sonet-alarm

A transmission problem is detected from
the transmitter.

Error

remote-sonet-alarm

A transmission problem is detected from
the receiver.

Error