Cuda 12000 IP Access Switch CLI-based Administration Guide

Configuring SNMP Event Notification Types

183

The following table lists the system events and their associated Event
Classes. For more information about Event Classes, refer to Chapter 10,
Managing System Events, on page 203.

Table 9-7 List of System Events

E

System Event

Description

Event Class

Cluster events:

Cluster events refer to faults that affect
the management module.

■

authentication-failure

SNMP receives a bad Community Name.

Notice

■

bcm-failover-down

Services are going down. This notification
type applies to redundant configurations
only.

Notice

■

bcm-failover-up

Services are coming up. This notification
type applies to redundant configurations
only.

Notice

■

bcm-state-change

A change in the craft port IP address.

Notice

■

bcm-sw-mismatch

The secondary will not come up because
its software revision does not match the
software revision of the primary.

Notice

■

trace-log

For ADC internal use only.

Notice

■

cold-start

Generated when module boots from
power up.

Notice

■

warm-start

Generated when module boots from reset. Notice

■

icl-state-change

A change in the ICL link.

Notice

Module events:

Module events refer to hardware faults
that affect any application module.

■

cable-modem-auth-failure

Cable modem failed authorization and did
not register.

Notice

■

cable-modem-down

Cable modem is not operational.

Critical

■

cable-modem-up

Cable modem is operational.

Notice

■

card-down

Application module failure.

Critical

■

card-up

Application module is operational.

Notice

■

dhcp-relay-not-configured

DHCP configuration error.

Warning

■

local-sonet-alarm

A transmission problem is detected from
the transmitter.

Error

■

remote-sonet-alarm

A transmission problem is detected from
the receiver.

Error