Cuda 12000 IP Access Switch CLI-based Administration Guide

Configuring SNMP Event Notification Types

193

Perform the following tasks to configure event notifications. Refer to the
configuration examples, below:

ospf-virt-nbr-state

Signifies a change in the state of an
OSPF neighbor on a virtual interface.
To send this notification type, note
that you also have to enable sending
of OSPF virtual neighbor state traps
using the report command.

Modem deregistration event:

A modem deregistration event refers
to the deregistration of cable
modems.

dereg-modems

Signifies that a number or percentage
of modems have deregistered over the
deregistration time interval.

Tasks

Commands

1. Enter configuration mode.

root

2. Create an SNMP host to receive

trap messages.

snmp-server host

<ip address>

<community-name> {traps | informs

[timeout

<seconds>]

[retries

<retries>]}

[version {1 | 2c | 3

{auth |

noauth | priv}]

3. Specify the UDP port number on

which the SNMP host will receive
traps.

snmp-server host

<ip address>

<community-name> {traps | informs

[timeout

<seconds>]

[retries

<retries>]}

[version {1 | 2c | 3

{auth |

noauth | priv}]

udp-port <port>

4. Specify the maximum message

size (MMS), in bytes, of an SNMP
message that the SNMP engine
will transmit or receive and
process.

snmp-server host

<ip address>

<community-name> {traps | informs

[timeout

<seconds>]

[retries

<retries>]} [version {1 | 2c | 3 {auth |
noauth | priv
}]

[mms]

<size>

Parameter

Description