Checking the auto calibration results, When “error code” appears, Message list after auto calibration measurement – Sony STR-DN1020 User Manual

Page 42

Advertising
background image

42

GB

D:\NORM'S JOB\SONY HA\SO0155\STR-DN1020_PMRF 03\4273051141_GB\GB04GET_STR-
DN1020-CEL.fm

masterpage: Left

STR-DN1020

4-273-051-14(1)

To cancel Auto Calibration

The Auto Calibration function will be
canceled when you perform the following
during the measurement process:
– Press ?/1.
– Press the input buttons on the remote control

or turn the INPUT SELECTOR on the
receiver.

– Press MUTING or

.

– Press SPEAKERS on the receiver.
– Change the volume level.
– Connect the headphones.
– Press SHIFT, then press AUTO CAL.

To check error code or warning message
obtained in “Performing Auto Calibration”
(page 40),
proceed with the following steps.

Press

V/v to select “Warning” in

step 7 in “Performing Auto
Calibration”
(page 41) then press

.

If a warning message appears, check the
message and use the receiver without change.
Or if necessary, perform Auto Calibration
again.

When “Error Code” appears

Check the error and perform Auto Calibration
again.

1

Press

to select “ENTER”.

“RETRY ?” appears on the TV screen.

2

Press

B/b to select “YES”, then press

.

3

Repeat steps 6 to 9 in “Performing Auto
Calibration” (page 40).

Message list after Auto
Calibration measurement

Tip

Depending on the position of the subwoofer, the
measurement results may vary. However, there will
be no problems even if you continue to use the
receiver with that value.

Checking the Auto Calibration
results

Display and explanation

Error Code 31
The SPEAKERS is set to off. Set to other speaker
settings and perform the Auto Calibration again.

Error Code 32
None of the speakers were detected. Make sure that
the optimizer microphone is connected properly
and perform the Auto Calibration again.
If the optimizer microphone is connected properly
but the error code still appears, the optimizer
microphone cable may be damaged.

Error Code 33
• None of the front speakers are connected or only

one front speaker is connected.

• The optimizer microphone is not connected.
• Either the surround left or surround right speaker

is not connected.

• Surround back speakers or front high speakers are

connected even though surround speakers are not
connected. Connect the surround speaker(s) to the
SPEAKERS SURROUND terminals.

• The surround back speaker is connected only to

the SPEAKERS SURROUND BACK/FRONT
HIGH/BI-AMP/FRONT B R terminals. When
you connect only one surround back speaker,
connect it to the SPEAKERS SURROUND
BACK/FRONT HIGH/BI-AMP/FRONT B L
terminals.

• Either the front left high or front right high

speaker is not connected.

Warning 40
The measurement process has completed with high
noise level detection. You may be able to achieve
better results if you try in a quiet environment again.

Warning 41
Warning 42
The input from the microphone is too big.
• The distance between the speaker and the

microphone may be too close. Set them apart and
perform the measurement again.

Warning 43
The distance and position of a subwoofer cannot be
detected. This may be caused by noise. Try to
perform the measurement in a quiet environment.

No Warning
There is no warning information.

Advertising