Features in 276-02

44

Version 276-05
C613-10474-00 REV D

CR00011510

IPsec

3

The maximum SPI value has been increased in the commands:

create ipsec saspecification=spec-id inspi=spi

outspi=spi [other parameters]

set ipsec saspecification=spec-id inspi=spi outspi=spi

[other parameters]

The spi is now an integer in the range 256 to 4294967295.

Y

Y

Y

Y

Y

-

-

-

-

-

CR00011659

TTY, VRRP

3

When VRRP debug was enabled from a telnet session, the debugging did not
stop when the telnet session closed. If the next telnet session got the same TTY
number as the closed session, VRRP debug output was displayed immediately the
session started. This made it possible for unauthorised users to view the debug
output.

This issue has been resolved.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00011687

BOOTP

3

The command set bootp relay maxhops is now supported, in addition to the
existing command set bootp maxhops.

Y

Y

Y

Y

Y

Y

Y

Y

Y

Y

CR00011774

Switch

3

The dot1qTpFdbPort MIB entry displays the ports on which the switch has
learned MAC addresses. Previously, the switch started the list of ports at port 0
instead of port 1.

This issue has been resolved.

-

-

-

Y

Y

Y

Y

Y

Y

Y

CR00011784

IP Gateway

3

If the router received an ARP response for an address outside of the receiving
interface's subnet, it discarded the ARP response. This is the intended behaviour
on some AR410 routers (see CR00010261) but not on AR7x5 routers.

This issue has been resolved. AR7x5 routers now forward such ARP responses.

-

Y

-

-

-

-

-

-

-

-

CR

Module

Level

Description

AR44x

S /

AR4

50S

AR7x5

AR750

S

Rapi

er

i

A

T-

880

0

A

T-

860

0

A

T-

870

0XL

A

T-

894

8

A

T-

990

0

A

T-

980

0

Advertising