Cross-Sectional

(A)+(B)

(A) Power Supply Wiring Length (ft)

(C) Control

Fuse or Circuit

Area (AWG)

(B) Power Line Length (ft)

Line Length (ft)

Model

(#14)

(#12)

(#14)

Breaker Capacity

CU-KE12NK1

131 (Max.)

230 (Max.)

65 (Max.)

20A

CU-KE18NKU

131 (Max.)

230 (Max.)

100 (Max.)

15A

# ... AWG (American Wire Gauge)

Table 4



Be sure to comply with local codes on running the
wire from the indoor unit to the outdoor unit (size
of wire and wiring method, etc.).



Each wire must be firmly connected.



No wire should be allowed to touch refrigerant
tubing, the compressor, or any moving part.



Be sure to connect the power supply line to the
outdoor unit as shown in the wiring diagram. The
indoor unit draws its power from the outdoor unit.



Do not run wiring for antenna, signal, or power
lines of television, radio, stereo, telephone, secu-
rity system, or intercom any closer than 3'3" (1 m)
from the power cable and wires between the
indoor and outdoor units. Electrical noise may
affect the operation.



To avoid the risk of electric shock, each air con-
ditioner unit must be grounded.



For the installation of a grounding device,
please observe local electrical codes.



Grounding is necessary, especially for units
using inverter circuits, in order to release
charged electricity and electrical noise caused
by high tension.
Otherwise, electrical shock may occur.



Place a dedicated ground more than 7' (2 m)
away from other grounds and do not have it
shared with other electric appliances.

*

A disconnect switch may be required by
national or local codes.

NOTE

WARNING

WARNING

CAUTION

Always comply with national and local code
requirements.

CAUTION

Fig. 7a

(CU-KE12NK1)

Disconnect
switch

*

1

2

3

1

2

3

4

5

6

Grounding line

115V

115V

115V

INDOOR

UNIT

OUTDOOR

UNIT

Field supply

Grounding
line

L

N

P

o

w

er supply

Single phase 115V 60HZ

Terminal

Terminal

(A)

(B)

(C)

(B)

Fig. 7b

(CU-KE18NKU)

Disconnect
switch

*

1

2

3

1

2

3

4

5

6

Grounding line

230/208V

230/208V

230/208V

INDOOR

UNIT

OUTDOOR

UNIT

Field supply

Grounding
line

L

1

L

2

P

o

w

er supply

Single phase 230/208V 60HZ

Terminal

Terminal

(A)

(B)

(C)

(B)

WIRING SYSTEM DIAGRAM