15

 For stranded wiring

(1) Cut the wire end with a cutting pliers, then strip the insulation to expose the stranded wiring about 3/8" (10 mm) and

tightly twist the wire ends. (Figs. 11 and 12)

(2) Using a screwdriver, remove the terminal screw(s) on the terminal plate.

(3) Using a ring connector fastener or pliers, securely clamp each stripped wire end with a ring connector. (Fig. 11)

(4) Place the ring connector wire, and replace and tighten the removed terminal screw using a screwdriver. (Fig. 13)

Fig. 11

Stranded wire

Ring
connector

Strip 3/8" (10 mm)

Fig. 12

Twist wire ends

Fig. 13

Screw

Ring connector

Terminal plate

Wire

Special
washer

Screw and
special washer

Ring
connector

Wire

4. How to Install the Outdoor Unit

First refer to Section 2. Installation Site Selection.

4-1. Wiring Instructions for the Outdoor Unit

Regulations on wire size differ from locality to locality.
For field wiring requirements, please refer to your
local electrical codes. Make sure that the installation
fully complies with all local and national regulations.

(1) Remove access panel “C”. (Fig. 14)

(2) Connect the inter-unit and power supply line

according to the drawing on the panel side.

(3) Be sure to size each wire allowing approx. 4"

(10 cm) longer than the required length for
wiring. Store excess wiring inside the cabinet.

(4) When connections are completed, check that all

connections are correct as shown in the wiring
system diagram on panel side.

(5) Be sure to ground the unit according to your

local codes.

Fig. 14

Lock nut

Conduit
plate

Plug

Inter unit
(Conduit)

Power supply
(Conduit)

Cabinet

Terminal
block

Access panel “C”