General – Panasonic KE12NB41 User Manual

Page 5

Advertising
background image

4

Printed on
container box

For unit & PVC
tube connection

For drain hose
connection

Remarks

Q’ty

For full-scale
installation
diagram

1

2

4

4

4

4

2

1

For temporarily
suspending indoor
unit from ceiling

Flare
insulation

For wide /
narrow tube
connection

For wide /
narrow tube /
flare nut connection

For flare / drain
insulating
connection

For drain tube
connection

Insulation tape

Vinyl tie

Drain hose
insulation

Washer

AAA alkaline
battery

Remote
controller

Remote control
holder

Parts

Parts

Figure

Remarks

Q’ty

Figure

Drain hose

Full-scale
installation
diagram

5-1/2"(L140)

Hose band

Truss head screw

Truss head screw

Special screw

Cushion rubber

Tapping screw

8

2

set

2

8

1

1

1

2

1/8"(T3)
3/16"(T5)

13/32"(T10)

3/32"(T2)

Truss-head Phillips

5/32 5/8"

(4 16mm)

3/16 13/32"
(5 10mm)

5/32 15/32"
(4 12mm)

3/16 1-9/16"
(5 40mm)

Packed in the
outdoor unit

Packed in the
ceiling panel

Use M10 or 3/8" for suspension bolts.
Suspension bolts and nuts (locally purchased)

Model

Narrow Tube

Wide Tube

Outer Dia.

Thickness

Outer Dia.

Thickness

CS-KE12NB41

1/4" (6.35 mm)

0.0314" (0.8 mm)

3/8" (9.52 mm)

0.0314" (0.8 mm)

CS-KE18NB4UW

1/4" (6.35 mm)

0.0314" (0.8 mm)

1/2" (12.70 mm)

0.0314" (0.8 mm)

1. General

This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instruc-
tions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning.

1-1. Tools Required for Installation (not supplied)

1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Carpenter’s level

6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits
9. Hammer

10. Drill

11. Tube cutter

12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for deburring)

1-2. Accessories Supplied with Unit

Table 1

1-3. Optional Copper Tubing Kit

Copper tubing for connecting the outdoor unit to the indoor unit is available in kits which contain the narrow and wide
tubing, fittings and insulation. Consult your nearest sales outlet or air conditioning workshop.

1-4. Type of Copper Tube and Insulation Material

If you wish to purchase these materials separately from a local source, you will need:

1.

Deoxidized annealed copper tube for refrigerant tubing as detailed in Table 2.
Cut each tube to the appropriate lengths 1' to 1'4" (30 cm to 40 cm) to dampen vibration between units.

2.

Foamed polyethylene insulation for the specified copper tubes as required to precise length of tubing. Wall thickness
of the insulation should be not less than 5/16" (8 mm).

3.

Use insulated copper wire for field wiring. Wire size varies with the total length of wiring. Refer to 3-7. Wiring
Instructions for details.

Table 2

CAUTION

Check local electrical codes
and regulations before
obtaining wire. Also, check
any specified instructions or
limitations.

Advertising
This manual is related to the following products: