Panasonic KE12NB41 User Manual

Page 21

Advertising
background image

20

How to Test Run the Air Conditioner

After turning on the power of the air conditioner, use the
remote controller and follow the steps below to conduct
the test run.

(1) Set the remote controller in Test Run mode. (Fig. 29)

a)Press and hold the HIGH POWER button and the

1HR. TIMER button.

b)Then press and hold the ACL (Reset) button with

a pointed object such as the tip of a pen. After 5
seconds, release the ACL button first.

c) Then release the HIGH POWER and 1HR. TIMER

buttons.

d)

appears and “oP-1” blinking in the remote con-

troller clock display area. (Fig. 30)

(2) Start Cooling mode test run by pressing the ON/OFF

operation button of the remote controller. (Fig. 29)

‡ 7KLVVWDUWVWKHIDQSURGXFLQJXQFRROHGIRUFHGDLU

with the 3 indicator lamps (OPERATION lamp,
TIMER lamp, and HIGH POWER lamp) on the
main unit blinking. (Fig. 31)

‡ $IWHUPLQXWHVWKHV\VWHPVKLIWVLQWRFRROLQJ

operation, and cool air will start to be felt. Cooling
mode test run is unaffected by the room tempera-
ture.

(3) Press the ON/OFF operation button of the remote

controller again to stop the test run. (Fig. 29)

(4) Finally press the ACL (Reset) button of the remote

controller to release it from Test Run mode to return
to normal mode. (Fig. 29)

‡ ´

µDQG´R3µZLOOGLVDSSHDUIURPWKHUHPRWH

controller clock display area.

Troubleshooting:
In the event that the green OPERATION lamp is blinking
upon powering up the system, an error condition exists.
In this case, refer to the self-diagnostics procedure
which can be seen by opening the air-intake grille.

After the test run is completed, be sure to press the ACL
(Reset) button to return to normal mode. The air condi-
tioner will not operate correctly if this is not done.

IMPORTANT

NOTE

Fig. 29

Fig. 30

Fig. 31

ACL
(Reset)

button

1HR.
TIMER
button

ON/OFF

operation

button

HIGH POWER
button

OPERATION lamp

TIMER lamp

HIGH POWER lamp

REMOTE CONTROL receiver

OPERATION button

Advertising