Panasonic KE12NB41 User Manual

Page 15

Advertising
background image

14

When connecting each power wire to the corresponding terminal, fol-
low the instructions “How to connect wiring to the terminal” and fasten
the wire securely tight with the fixing screw of the terminal plate.

How to connect wiring to the terminal

a) For Indoor Unit

(1) Cut the wire end with a cutting pliers, then strip the insulation to

expose the wire about 9/32" (7 mm). See the label (Fig. 9) near the
terminal plate.

(2) Using a screwdriver, loosen the terminal screw on the terminal

plate.

(3) Insert the wire and tighten the terminal screw completely using a

screwdriver.

b) For Outdoor Unit

 For solid core wiring (or F-cable)

(1) Cut the wire end with a cutting pliers, then strip the insulation to

expose the solid wire about 15/16"
(25 mm). (Fig. 10)

(2) Using a screwdriver, remove the terminal screw(s) on the terminal

plate.

(3) Using the pliers, bend the solid wire to form a loop suitable for the

terminal screw.

(4) Shape the loop wire properly, place it on the terminal plate and fix

it securely with the removed terminal screw using a screwdriver.

Loose wiring may cause the ter-
minal to overheat or result in unit
malfunction. A fire hazard may
also exist. Therefore, be sure all
wiring is tightly connected.

WARNING

Fig. 9

STRIP
SIZE

9/32"

(7 mm) (ACTUAL

SIZE)

Fig. 8

Fig. 10

Solid wire

Loop

Insulation

Strip 15/16" (25 mm)

1

3

2

Earth screw

Clamping strap

(Conduit)

Inter unit

Power wiring
(Locally purchased)

3-9. Wiring Instructions for Inter-unit Connections

(1) Remove the 1 screw from the terminal cover, then open the

cover. Be careful that the cover does not fall.

(2) Remove the 3 screws from the power box cover, then open

the cover. Be careful that the cover does not fall.

(3) Use the screw to securely fasten the ground wire from the

outdoor unit in place.

(4) Remove the transparent plastic cover from the 3P terminal

plate.

(5) While viewing the wiring diagram, connect the inter-unit and

power supply line to terminals 1, 2 and 3 on the 3P terminal
plate.

(6) Remount the transparent plastic cover onto the 3P terminal

plate.

(7) Be sure to use the clamping strap to fasten the wires in place.

(8) Tighten the screws to remount the terminal and the power

box cover.