Equipment, Temperature class and maximum liquid temperatures, Technical support & service – Pulsafeeder Eclipse Model 75 User Manual
Page 134

128
Equipment
Equipment in Group II, Category 2, is intended for use in areas in which explosive atmospheres caused by gases, vapors,
mists or air/dust mixtures are likely to occur.
G & D Atmospheres
In G type Explosive atmosphere (Gas, vapor, mist) equipment is suitable for use in Zone 1 areas.
In D type Explosive atmosphere (Dust) equipment is suitable for use in Zone 21 areas.
Temperature
Class
Temperature class TX based on ambient and pumped fluid temperature.
Different temperature classes can be achieved based on fluid and ambient temperatures (See chart)
Temperature Class and Maximum Liquid
Temperatures
Temperature
Class
Maximum Surface
Temperature C
Permitted
Max. Liquid or Ambient Temperature C
Comments
(Dust)
Sealed Pumps
Magnetic Drive
T1
450
260
230
Fluid temperatures are
limited by pump
construction
T2
300
225
225
T3
200
145
145
T4
135
90
90
T5
100
65
65
*T6
85
50
50
Normal class rating
* Maximum Temperature Class for Eclipse Standard/Eclipse Hypo Series Pumps is T6.
Technical Support & Service
For technical support or service contact:
Pulsafeeder
Inc.
2883 Brighton Henrietta Townline Road
Rochester,
New
York
14623
USA
(585) 292-8000
Protective Earth Ground Symbol