Model identification - eclipse hypo, Model identification – eclipse hypo – Pulsafeeder Eclipse Model 75 User Manual
Page 54

48
13. Model Identification – Eclipse Hypo
Position
Sample
Specifies
Options
1 and 2
EH
EH - Eclipse Hypo
3 and 4
02
Size
02
05
12
25
75
125
5 K
Base Material
K – Carbon filled PVDF, FNPT
and Connections
B – Carbon filled PVDF, BSPT, ISO 7-1
N – Carbon filled PVDF, Flanged
6 L
Bearings
B - Silicon-Carbide
7 V
O-rings
V – FKM “A”
8 F
Motor
F - NEMA 56C
Mounting
O - NEMA 143TC-182C
R - NEMA 182-184TC
W - NEMA 213TC – 215TC
H - IEC B3/B14 63
J - IEC B3/B14 71 (special order)
K - IEC B3/B14 80
L - IEC B3/B14 90 (special order
E125 only)
P - IEC B3/B14 100/112
Y - No motor mount kit
9 -
position 9 is a dash
10 X
Options
X – Complete Pump (No Options)
A – Bearing Flush Ports
N – Pump Wet End Only
B – Options A and N
In the above example, the Eclipse Standard pump EH02KBVF-X is a Model 02 pump, Carbon filled PVDF base materials, FNPT
process connections, Silicon-Carbide bearings, FKM O-rings, and a NEMA 56 motor mounting.
Options Description for both Eclipse Standard/Eclipse Hypo:
Complete pump model number with no magnet options (“X” or “A” in position 9 (Standard) / position 10 (Hypo)) includes drive
magnet and all necessary motor mounting hardware for a specified motor size.
Option “Y” in position 7 (Standard) / position 8 (Hypo) is for a bare pump with drive magnet, but no motor mounting hardware
(magnet hub, motor adapter when applicable). This will typically be used as a spare pump or as inventory until a specific motor size is
identified.
Option “N” in position 9 (Standard) / position 10 (Hypo) is for a bare pump without the drive magnet. This will typically only be used
as a “wet end” repair kit for an existing unit when the drive magnet is not required with the new pump. This option can only be used
in combination with a “Y” code in position 7 (Standard)/position 8 (Hypo).
Consult factory for availability of option combinations not covered in the above chart.