8.

Disassembly/Assembly, Eclipse Standard/Eclipse Hypo 25/75/125


B

EFORE PERFORMING ANY MAINTENANCE REQUIRING PUMP DISASSEMBLY

,

BE SURE TO RELIEVE

PRESSURE FROM THE PIPING SYSTEM AND

,

WHERE HAZARDOUS PROCESS MATERIALS ARE INVOLVED

,

RENDER THE PUMP SAFE TO PERSONNEL AND THE ENVIRONMENT BY CLEANING AND CHEMICALLY

NEUTRALIZING AS APPROPRIATE

.

W

EAR PROTECTIVE CLOTHING AND EQUIPMENT AS APPROPRIATE

.

8.1 Disassembly

Close all suction and discharge valves.
Disconnect power source to motor.
Flush and drain pump
Remove piping (optional for KOPKit).
NOTE: The can area will not fully drain and will contain some process fluid

1. Remove the four motor bolts and washers (items 22, 23) and slide the entire pump straight off the motor.

Figure 34

2. Place pump assembly (motor spool down) on the work surface.

3. Remove the six bolts and washers (items 3, 4), remove front cover (item 5) and nut plates (item 28) as shown.

4. If required, the mounting base (item 32) can be detached by removing the four bolts and washers (items 33,

34) as shown.