10. Place the front cover (item 5) with o-ring onto the assembled pump. Secure the front cover using the six bolts
and washers (items 3, 4) and two nut plates (item 28) as shown. The flat side of the nut plates mates against
the back of the center housing flange. Tighten bolts to the torque specified in Section 12. Always tighten
fasteners in a progressive “crisscross” pattern.
Figure 44
11. Secure the mounting base (item 32) to the motor spool (item 20) using the four bolts and washers (items 33,
34) as shown. Always tighten fasteners in a progressive “crisscross” pattern.