6. Install o-rings (items 6, 15) into grooves on both sides of the center housing. Some o-ring lubricant may help

keep the o-rings in place during assembly. Be sure both o-rings are fully seated into housing grooves.

Figure 11

7. Place the center housing (item 14) with o-rings installed onto the spool adapter plate (open bore facing out),

aligning the flat sides on the center housing to the flat sides on the spool adapter plate as shown. If the center
housing does not sit flat, rotate 180º until it seats into place.

8. Secure the center housing using 2 bolts (item 7) in holes as shown. Tighten these bolts to the torque specified in

Section 12. Always tighten fasteners in a progressive “crisscross” pattern.

Figure 12