1

st

Screen

ProductionVIEW HD-SDI

V01.00.00 (software version)

Rescan Cameras

Video Output

Video Input


Rescan Cameras

>Select (Note: Rescans all RS-232 ports for camera inputs)

>Start



Rescan Video

>Select (Note: Resets all inputs, outputs and video processor)

>Start



Video Output Menu

>Select

>Video Output

>Program Output

HD 1080p 30 Hz

HD 1080p 25 Hz

HD 1080i 59.94 Hz

HD 1080i 50 Hz

HD 720p 60 Hz
HD 720p 59.94 Hz

HD 720p 50 Hz

SD 480i 29.97 Hz

SD 576i 25 Hz


>Preview Output (NOTE: Same resolution options as Program Output menu)



Video Input Menu

>Select

>All Ports (NOTE: Selecting ALL PORTS will configure all inputs to the same resolution)
Port 1

(NOTE: Same resolution options as Program Output menu)

Port 2
Port 3
Port 4
Port 5
Port 6


Default Camera (Automatic and Start-up Modes – the default input selected on the Program bus when the system is turned on)

>Select

> 01 – 06
Selects inputs 1 through 6 as the default camera (default is 01)




Default Preset (Automatic Mode – the default preset that the camera is sent to when the system is in Auto Mode. Only reverts to
the configured default position after a trigger has been activated in Auto Mode)

>Select

> 01 – 12

Assigns camera preset 1 through 12 as Default Preset on the default camera (default is 01)




Default Idle Rtn (Automatic Mode only using an external trigger such as a StepVIEW Mat)

>Select

>00 – 60
Default Camera Idle Return Timer - with no other trigger input, the system returns to the Default Camera and
Default Preset after this time elapses (default is 10, 00 disables function)