Vaddio ProductionVIEW HD-SDI User Manual

Page 16

Advertising
background image

ProductionVIEW HD-SDI

>Preset Location

>Local

>6 InCam 6 Local
In “Local” mode, the ProductionVIEW stores all 12 presets internally
In “6 InCam 6 Local” mode, the presets 1 through 6 will be stored in the cameras.
Presets 7 through 12 will be stored in the ProductionVIEW.

Note:

The “6 InCam 6 Local” mode allows for switching video sources when cameras are moving

to preset locations. Since Presets are stored in Camera, the system does not have

to wait for position feedback before allowing another command to be entered.


>Switching Mode

>Select

>Single Mode (Default)

>Dual Mode


>Transition Swap (Default is On)

>On

>Off


>Settle Time (Default is 20)

>Select

>01 to 90

Note:

Settle time allows the user to set up the time delay between pressing the Take button and
when the next button can be selected on the console. With a lower settle time, there is a
greater chance that a blue screen will appear on the Program output, when the video is
switched quickly, and repeatedly. In most applications this will not be an issue. In Single
Bus Mode, a faster Settle Time will also create a video roll on the Preview output, which
again in most situations will not be an issue.



>FTB Time (Default is 10)

>Select

>10 to 40

Note:

FTB Time allows the user to set up a length of time that a fade to black on the Program
Output will occur. 10 is equal to 1.0 seconds, 11 is equal to 1.1 seconds, etc. FTB is
executed on ProductionVIEW HD by pressing and holding the Mix/FTB button for more
than 2 seconds.



>Program Lockout (Default is On)

>Select

>On

>Off


>Gen Lock (Default is Off)

>Off

>HD 1080i 59.94 Hz

>HD 1080i 50 Hz
>HD 720p 59.94 Hz
>HD 720p 50 Hz

>SD 480i NTSC

>SD 576i PAL



>Home (Default is On)

>Off

>On


>Init Triggers

>Start




Note: Gen Lock allows the user to send the preview and program outputs
to a master control switcher or routing matrix that requires a synchronized
signal. NOTE: The Gen Lock input, preview and program outputs must
all be at the same resolutions.

Note: Program Lockout prevents a user from selecting a different source on the
Program bus of the switcher. All switching of inputs must be accomplished by
selecting an input on the Preview bus, and then pressing the Take button.

NOTE: See page 2 for additional information on Dual Bus mode,
as well as descriptions on pages 9 – 12.

Note: Turning off the Home feature prevents the camera from going to
the home position when the button on top of the joystick is pressed.

Note: When any trigger devices (i.e. StepVIEW Mats, etc.) are added or removed,
the user must initiate the Start command to recognize what input triggers are
currently connected to the system.

ProductionVIEW HD-SDI Manual 341-852 Rev. B

Page 16 of 22