Getting Started:
First, set up the HD and SD output resolutions for the camera, along with IR output, baud rate and image
flip. On the next page are the options for the switches that are found on the back of the camera.

Figure 5: Dip Switch and HD Video Output Resolution Setting Options for the HD-18 Camera














Note: The Test Bars are non standard, but are 75% YCbCr Color Bars and are intended as a
convenience for testing the signal path only.
 IR 1, 2 & 3: These settings, using switches 1 & 2, determine the IR frequency of the IR remote control

that was supplied with your camera. The IR remote has the capability of operating up to three different
PTZ cameras from one remote, using the selector buttons at the top of the remote.

 IR Out: The IR output is sent on the RJ-45, RS-232 jack on the back of the camera. Turning on the IR

output will allow IR signals to be transmitted over the CAT-5 cable.

 Baud Rate: The options for baud rate are either 9600 or 38,400 for RS-232.

 SD Output Frequency: Select either NTSC or PAL as the output for the camera’s SD signal that is

transmitted on the BNC connector.

 SD Output Size: Three options are available for the SD output, select from crop, squeeze or letterbox.

 Image Flip: Turing Image Flip on (switch down), will allow the camera to be inverted.

 Test Bars: Turning this switch on will override the camera video output and send test video bars from

the camera to the CCU to allow more accurate setting of the video level at the CCU.

 Switch 10: This switch is unused, and should be left in the OFF position.


Before Installing

 Locate the camera mounting location paying close attention to camera viewing angles, lighting

conditions, possible line of site obstructions, and checking for in-wall obstructions where the camera
is to be mounted. Pick a mounting location to optimize the performance of the camera.

 Pre-wire all cabling as required (see wiring diagram examples).

 The CONCEAL Wall Mounting System for the WallVIEW HD-18 can be mounted directly to a 2-gang

wall box or can be mounted to the drywall using the supplied four (4) drywall anchors.















IR 1

1 & 2 UP

ON

SD

NTSC

SD

PAL

SD 4:3

6 & 7 UP

SD
LB

IMAGE

FLIP

OFF

ON

ON

DIP SWITCH SETTINGS

8

1

2

3

4

5

6

7

9

10

HD VIDEO SELECT

720p/59.94

1080i/59.94

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

1080p/59.94

1080p/60

720p/50

1080i/50

1080p/50

2

1

5

4

3

7

6

8

10

9

ON

IR 2

ON

IR 3

ON

IR

OUT

OFF

9600

bps

38400

bps

SD

SQ

TEST

BARS

OFF

10

OFF

480i/29.97

1080p/25

1080p/30

576i/25

Advertising