37

Useful information concerning the energy
consumption of electric ovens.

This information completes and expands
on the figures provided on the technical
data sticker supplied with the instruction
manual.

Cooker
55N Static

EU environmental quality
mark.

No

Time required to cook a normal
load in conventional mode in
minutes.

53,4

Time required to cook a normal
load in fan mode in minutes.

...

Power consumption in
stand-by setting in Watts.

...

Usable area of the dripping
pan in cm

2

1156

INSTALLATION
The appliance must be installed by qualifi ed
staff working in accordance with the regula-
tions in force.Before installing, ensure that
the appliance is correctly preset for the local
distribution conditions (gas type and pres-
sure).The presettings of this appliance are
indicated on the nameplate shown on the
cover.This appliance is not connected to a fl ue
gas extractor device. It must be installed and
connected in accordance with the regulations
in force.This appliance may only be installed
and may only operate in rooms permanently
ventilated in accordance with national regula-
tions in force.

VENTILATION
The rooms in which gas appliances are in-
stalled must be well ventilated in order to allow
correct gas combustion and ventilation.
The air fl ow necessary for combustion is at
least 2 m

3

/h for each kW of rated power.

POSITIONING
Remove the packaging accessories, includ-
ing the fi lms covering the chrome-plated and
stainless steel parts, from the cooker. Position
the cooker in a dry, convenient and draft-free
place. Keep at an appropriate distance from
walls which may be damaged by heat (wood,
linoleum, paper, etc.).The cooker may be
free-standing (class 1) or between two units
(in class 2 st 2-1) the sides of which must
withstand a temperature of 100°C and which
must not be higher than the working table.
“Class 1” means the appliance should not
be built into cabinets. The minimum clearance
between the appliance and kitchen cabinets
on either side situated beneath the worktop or
the lid when closed is 20 mm. The minimum
clearance between the appliance the wall
on either side is 20 cm. In the presence of a
cooker hood, the latter should be situated at
least 65 cm above the worktop, and adjacent
cabinets should be at least 42 cm away. If
there is no cooker hood, the cabinet installed
in its place should be situated at least 70 cm
away.
“Class 2 subclass 1” means the appliance
should be built in between two cabinets. The
minimum clearance between the appliance
the wall on either side is 20 cm. In the pre-
sence of a cooker hood, the latter should be
situated at least 65 cm above the hob, and
adjacent cabinets should be at least 42 cm
away. If there is no cooker hood, the cabinet
installed in its place should be situated at least
70 cm away.
“Type X kitchen” refers to the method for
connection of the power supply cable (fl exible
cable), which must be such as to allow easy
replacement.

CONNECTING TO THE GAS SUPPLY
Before connecting the cooker, check that it
is preset for the gas to be used. Otherwise,
make the conversion as described in the
section headed "Adapting to different gas
types". The connection is on the right; if the
pipe has to pass behind the cooker, it must

Installation

GB