3 mechanical instalation, 4 configuration, 1 configuration via usb interface – NOVUS RHT-Air User Manual

Page 2: 5 electrical installation, 1 external power supplying

Advertising
background image

NOVUS AUTOMATION

2/8

2.1 PRECISION OF MEASUREMENTS AND OPERATIONAL LIMITS OF SENSORS:

Fig. 3 - Precision of the humidity and temperature measurement

3 MECHANICAL INSTALATION

RHT-Air was designed to be attached to walls. By removing the equipment’s

cover, users will have access to two molding holes of the base, as shown in

Fig. 4. The equipment should be attached with the sensor capsule

facing downwards in order to ensure precision and the specified level

or protection.

Fig. 4 - RHT-Air mounting holes and measures

Fig. 5 - RHT-Air Measurements

4 CONFIGURATION

4.1 CONFIGURATION VIA USB INTERFACE

Initially, the first configuration must be done through USB interface.
• Remove the four set screws of the front panel of the equipment RHT-Air,

taking the necessary precaution not to apply force on the internal connector

of the electronic circuit.

• In order to configure it through a USB interface, connect the cable as

shown below. The external power cord should not be used during the

configuration.

5 ELECTRICAL INSTALLATION

5.1 EXTERNAL POWER SUPPLYING

Fig. 6 below shows RHT-Air’s necessary electrical connection. Terminals

1 and 2 are to be used in the electrical connection and terminals 3 and 4

are not used.

1

- VDC

Power Supply

Black wire

2

+ VDC

Power Supply

White Wire

3

Not used

Blue wire

4

Not used

Brown Wire

Advertising