AirGate-GPRS

NOVUS AUTOMATION

11/29

INPUTS

There are two input channels that can be individually configured using internal jumpers such as input 4-20 mA, input 0-10 V
or digital input. There is no insulation between channels.

The jumper access requires the opening of the AirGate-GPRS. Their location can be seen in the following illustration:

*

The AirGate-GPRS is factory configured as a digital input in both channels.

Digital Signal Wiring

When configured as a digital input, it can be connected to a voltage output (check the acceptable levels in the
Specifications section), a dry-contact output or a NPN output. Be careful when connecting multiple outputs due to the
lack of insulation between the AirGate-GPRS inputs.

Fig. 04 - Voltage connection

Fig. 05 – Dry-contact connection

Fig. 06 – NPN connection

Connection Current (mA)

Channels connection in the terminals should be done as shown in the figure on the left.
Check the correct connection polarity.