NOVUS myPCLab EN User Manual

Page 2

Advertising
background image

myPCLab

NOVUS AUTOMATION

2/9

Timing: It times up to 4294967295 miliseconds (more than 49 days). It is selectable to run timing when
input in logic level "0" or when in "1". Accuracy: 0.5 % of the indicated time.

Frequency: It counts the number of pulses (rising edge, falling edge or both) in each base time,
configurable from 1 to 65535 seconds (18 hours). Maximum input frequency: 500 Hz (square wave, no
debounce). Maximum input frequency: 500 Hz (square wave, no debounce). Accuracy: 0.5 %.

Ambient Temperature Sensor: Internal thermistor.

Total Accuracy: Thermocouples R, S and B: 0.25% of the maximum range ± 3 °C (with maximum A/D resolution);

Other thermocouples: 0.25% of the maximum range ± 1 °C (with maximum A/D resolution);

Pt100, voltage and current: 0.20% of the maximum range (with maximum A/D resolution);

Ambient temperature channel: ± 1.5 °C (after 20 minutes connected to the USB port).

A/D Resolution: Configurable from 15 to 11 bits.

Input Sampling Rate: From 8 to 128 samples per second, depending on configured A/D resolution and number of

enabled channels.

Computer Interface: USB V1. 1 Plug and Play, virtual serial port interface.

USB connection: Mini-B receptacle.

Power supply: From the USB bus. Typical current 30 mA.

Operating environment: 0 to 50°C, 10 to 90% relative humidity, non-conden sing.

Electromagnetic Compatibility: EN 50081-2, EN 50082-2.

Built-in cold junction compensation for thermocouples and wire resistance for Pt100.

ABS case, dimensions: 70 x 60 x 18 mm. See figure.

Advertising