0-50 mV WIRING

Connections of channel 1 are on terminals 6 and 7. For channel 2 on terminals 2 and 3.
Observe indicated polarity.

0-10 V WIRING

Linear voltage signals from 0 to 10 V can only be connected to channel 1, terminals 5 and 6.
Observe indicated polarity.

DRY CONTACT DIGITAL INPUT WIRING

Digital signals are connected to channel 3, terminals 1 and 2.

The contact connected to digital input must not have any electrical voltage.

VOLTAGE DIGITAL INPUT WIRING

Digital signals are connected to channel 3, terminals 1 and 2. Observe indicated polarity.

Voltage levels applied to this channel must be within the specified limits. See “Specifications”.