Installation
Check
Explanation/comment
Checked
When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the Mesh holes with a minimum diam-
suction piping.
eter of 1/16 in. (1.6 mm) are
recommended.
If more than one pump operates
This recommendation helps you
from the same liquid source,
to achieve a higher pump perfor-
check that separate suction-piping mance.
lines are used for each pump.
If necessary, make sure that the
—
suction piping includes a drain
valve and that it is correctly in-
stalled.
Liquid source below the pump
Check
Explanation/comment
Checked
Make sure that the suction piping
This helps to prevent the occur-
is free from air pockets.
rence of air and cavitation in the
pump inlet.
Check that the suction piping
—
slopes upwards from the liquid
source to the pump inlet.
Check that all joints are air-tight.
—
If the pump is not self-priming,
Use a foot valve with a diameter
check that a device for priming the that is at least equivalent to the
pump is installed.
diameter of the suction piping.
Liquid source above the pump
Check
Explanation/comment
Checked
Check that an isolation valve is
This permits you to close the line
installed in the suction piping at a
during pump inspection and main-
distance of at least two times the
tenance.
pipe diameter from the suction
Do not use the isolation valve to
inlet.
throttle the pump. Throttling can
cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty
Make sure that the suction piping
This helps to prevent the occur-
is free from air pockets.
rence of air and cavitation in the
pump inlet.
Check that the piping is level or
—
slopes downward from the liquid
source.
Make sure that no part of the
—
suction piping extends below the
suction flange of the pump.
Make sure that the size of the
—
entrance from the supply is one or
two sizes larger than the suction
pipe.
Make sure that the suction piping
This prevents air from entering the
is adequately submerged below
pump through a suction vortex.
the surface of the liquid source.
34