Goulds Pumps 3298 - IOM User Manual

Page 36

Advertising
background image

Installation

Check

Explanation/comment

Checked

When suction strainers or suction Suction strainers help to prevent
bells are used, check that they are clogging.
at least three times the area of the Mesh holes with a minimum diam-

suction piping.

eter of 1/16 in. (1.6 mm) are
recommended.

If more than one pump operates

This recommendation helps you

from the same liquid source,

to achieve a higher pump perfor-

check that separate suction-piping mance.
lines are used for each pump.
If necessary, make sure that the

suction piping includes a drain
valve and that it is correctly in-
stalled.

Liquid source below the pump

Check

Explanation/comment

Checked

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Check that the suction piping

slopes upwards from the liquid
source to the pump inlet.
Check that all joints are air-tight.

If the pump is not self-priming,

Use a foot valve with a diameter

check that a device for priming the that is at least equivalent to the
pump is installed.

diameter of the suction piping.

Liquid source above the pump

Check

Explanation/comment

Checked

Check that an isolation valve is

This permits you to close the line

installed in the suction piping at a

during pump inspection and main-

distance of at least two times the

tenance.

pipe diameter from the suction

Do not use the isolation valve to

inlet.

throttle the pump. Throttling can
cause these problems:
• Loss of priming
• Excessive temperatures
• Damage to the pump
• Voiding the warranty

Make sure that the suction piping

This helps to prevent the occur-

is free from air pockets.

rence of air and cavitation in the
pump inlet.

Check that the piping is level or

slopes downward from the liquid
source.
Make sure that no part of the

suction piping extends below the
suction flange of the pump.
Make sure that the size of the

entrance from the supply is one or
two sizes larger than the suction
pipe.
Make sure that the suction piping

This prevents air from entering the

is adequately submerged below

pump through a suction vortex.

the surface of the liquid source.

34

3298 Family Installation, Operation, and Maintenance Manual

Advertising